Assessment of Chloramine and Chlorine Residual Decay in the Distribution System
Book Details
Format
Paperback / Softback
Book Series
Water Research Foundation Report Series
ISBN-10
1843399741
ISBN-13
9781843399742
Publisher
IWA Publishing
Imprint
IWA Publishing
Country of Manufacture
GB
Country of Publication
GB
Publication Date
Mar 1st, 2007
Print length
220 Pages
Dimensions
23.40 x 15.60 x 1.80 cms
Product Classification:
Environmental science, engineering & technology
Ksh 22,700.00
Manufactured on Demand
Delivery in 29 days
Delivery Location
Delivery fee: Select location
Delivery in 29 days
Secure
Quality
Fast
Maintaining chlorine and chloramine residual is a key factor that determines potability of distributed water. Decay of these disinfectants is affected by various water quality and infrastructure related factors. Understanding the decay of residuals in the distribution system is critical with respect to safe delivery of drinking water and in developing water quality models that can be used by utilities for the operation of potable water delivery systems. In order to comply with microbial and disinfection byproduct (M/DBP) regulations, water suppliers are continually investing in treatment processes for achieving greater levels of inactivation and DBP precursor removal. As a result of these changes in water quality, maintaining a disinfectant residual in the distribution system can be challenging Bench-scale testing has been used to determine the effect of advanced treatment (enhanced coagulation, granular activated carbon adsorption, ozonation, biofiltration, and ultraviolet irradiation) on chlorine and chloramine decay. Additional studies examine the effects of disinfectant dose, temperature, pH, blending, and rechlorination. The effects of water quality on pipe-wall demand were evaluated using the distribution system simulator at the U.S. Environmental Protection Agency's Test and Evaluation Center. Several models are developed regarding disinfectant decay, making it easier to predict chlorine demand after changes in treatment. The multi-species water quality analysis and network path analysis extensions to EPANET will make the modeling package more robust and will allow utilities to predict chlorine residual at any point in their distribution system with greater confidence.
Get Assessment of Chloramine and Chlorine Residual Decay in the Distribution System by at the best price and quality guaranteed only at Werezi Africa's largest book ecommerce store. The book was published by IWA Publishing and it has pages.